Pramac Generators. Ridgid Generator Manuals. Ryobi Generator Manuals. Sears Craftsman Generator Manuals. Troy-Bilt Generator Manuals. Yamaha Generator Manuals. Nailer Manuals. Paint Sprayers Manuals. Power Tools. Pressure Washer Manuals. These receptacles may be used along with the twistlock receptacle provided the generator is not overloaded. However, current must be limited to the nameplate rating. Circuit Breakers The receptacles are protected by an AC circuit breaker.
If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load.
NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker. This one year warranty applies only to products used in consumer applications. If this generator is used in a commercial application, then the period of warranty coverage is limited to ninety 90 days from the date of purchase.
Please complete and return the enclosed Customer Information Card so that we can reach you in the unlikely event a safety recall is needed. Return of this card is not required to validate this warranty. Generator Head C. However, current must be limited to the nameplate rating. Storage Bin M. Oil Drain N. Pneumatic Tires O. Retractable Handles D. Circuit Breakers The receptacles are protected by an AC circuit breaker.
If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.
Handle Release Buttons To extend the handles, press the handle release buttons on the wheel end of the unit. Pull the handles out until the handle release buttons lock in place on the engine end of the unit. To retract the handles, press the handle release buttons on the engine end of the unit. Push the handles in until the handle release buttons lock in place on the wheel end of the unit.
Panel Light The panel light comes on automatically when the engine is started. The light goes off automatically when the engine is shut off.
Engine Choke Lever G. Fuel Shut-Off www. Serious injury or death may result from fire caused by gasoline contacting hot surfaces. Do not fill fuel tank with engine running.
Do not spill fuel while refilling tank. Do not mix oil with gasoline. Do not start or run the generator in an enclosed area, even if door or windows are open. Engines give off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide can cause nausea, fainting or death. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output.
Readjusting will void warranty. This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire. Check oil level and fuel. Disconnect all electrical loads from the unit. Open fuel shut off valve. Adjust choke as necessary.
Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke. Release key switch after the engine starts. When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle. Remove entire electrical load. Let the engine run for two minutes without load. Do not leave the generator until it has completely stopped. Close the fuel shut off valve if the engine is to be put in storage or transported.
If a cover is used, do not install until unit has cooled. Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize. Follow engine procedure outlined in engine manual.
Plug a lamp or light into the generator before starting the engine. The light source will illuminate when voltage has returned. Start the engine with no load connected to the generator.
Attach the "-" lead of the battery to the negative brush. Remove as soon as voltage builds up. To measure voltage, use a plug-in voltmeter. Do not apply heavy electrical load during break-in period the first two to three hours of operations. NOTE: Replace brushes in sets only, never separately. Remove cover plate R. Remove 4 stator bolts U and endbell. Remove screws holding the protective plate on the inside of the endbell.
Remove brush mounting screws S. Slide brushes T from holders. Do not over tighten screws. Do not remove any parts or modify parts. Removing or modifying parts could cause serious damage to the unit. If this develops, the engine may run rough, loose power, and may stall. Call Product Service for more information. NOTE: Refer to the engine manufacturer's manual for service and maintenance of the engine. NOTE: Replace only with brushes specified in parts list.
Other brushes may appear to be identical but may have completely different mechanical and electrical characteristics. Check the oil level. Replace the old fuel. Change the spark plug. Check the fuel lines. Make sure the fuel valve is open. Check all generator parts for integrity. Clean the Carburetor. Use a 6-volt lantern battery dry cell or a volt automotive battery.
Disconnect all loads from generator. Remove the brush cover. Also, if the unit will not be used for some time, it is a good idea to drain the fuel from the carburetor and gas tank. Repeat above instructions for the remaining wheel. Caution: Do not over tighten so that the foot material collapses.
Blocking up the alternator side of the generator, place the foot bracket under the carrier channel. Place handle item 28 over carrier tubing on same end as feet, centering handle on the carrier. Tighten until handle is securely clamped to the carrier tubing.
Apply aerosol hairspray or similar adhesive to the handle item 28 , and then slide the handle grip item 44 onto the handle. The aerosol hairspray will allow for easier assembly and will adhere the grip to the handle. NOTE: When using a generator cover with this portability kit, the handle must be moved to the downward position. Prise double de V, 20 A. Les balais, les fusibles, les pieds en caoutchouc et les prises de courant femelles.